• 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor
  • 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor
  • 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor
  • 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor
  • 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor
1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor

Product Details:

Place of Origin: DONGGUAN,GUANGDONG,CHINA
Brand Name: FUSEI
Certification: CQC/CCC/UL
Model Number: Y 3A 250V

Payment & Shipping Terms:

Minimum Order Quantity: 1000PCS
Price: Negotiable
Packaging Details: Bulk,1000pcs per bag
Delivery Time: 7-10 workdays
Payment Terms: T/T, Western Union
Supply Ability: 50000pcs per day
Get Best Price Contact Now

Detail Information

Name: Temperature Thermal Cutoff Fuse Rated Current: 3A
Rated Voltage: 250V Housing: Insulated Plastic
Alloy: Low Melting Point Alloy Coating: Special Resin
Lead: Tinned Plated Copper Certifications: UL,CCC,CQC
Rated Operating Temperature Tf: 75~150 Deg Breaking Current: 4.5A
Limited Time Overload Current: 45A Limit Temperature: 180 Deg
High Light:

10A Thermal Cutoff Fuse

,

3A Thermal Cutoff Fuse

,

250V Fan Motor Fuse

Product Description

 

Metal Ceramic Type 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse for Fan Motor

 

1 Product description Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

A thermal fuse or thermal cutoff is a safety device which open circuits against overheat. It detects the heat caused by the over-current due to short circuit or component breakdown. Thermal fuses do not reset themselves when the temperature drops like a circuit breaker would.

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 0

Y series thermal fuse introduction: thermal fuse is composed of fuse wire and insulated shell, mainly used in electrical and electronic product equipment and its parts. It is mostly used in indoor electrical equipment, mainly to protect electrical equipment from overheating under abnormal conditions. Once the fuse is to be reset, only the temperature fuse of the same type and specification can be used.

 

 

2 Working principle Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

When the temperature of the equipment rises abnormally, the thermal fuse is induced to heat, and when the temperature reaches the set temperature of the alloy, the low melting point is melted, and the surface tension of the molten alloy increases under the action of the special resin, causing the alloy to shrink in a spherical shape. On the lead wire, the circuit is completely cut off.

 

 

3 Anatomy Diagram Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 1

a b c d e
Insulation Case Low melting point alloy

Special resin

Seal resin

 

Tinned plated copper

 

 

4 Product installation guidelines Of The The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 2

 

* Keep a distance of 3mm from the fuse body when bending the wire.

* When welding or soldering exceeds the rated temperature of the fuse, the longer the welding distance and the shorter the welding time, the less damage to the fuse.

* Be careful of the current flowing in the insurance body.

* Do not use liquids or toxic gases such as sulfuric acid and nitric oxide.

* Do not connect the heater and the fuse directly.

 

 

5 Dimension Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse (mm)

 

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 3

A B C D E※
6.1±0.2 6.8±0.2 2.6±0.2 0.5±0.02 70±2
5.1±0.2 5.4±0.2 2.4±0.2 0.5±0.02 50±2

Length can be customized on request

 

 

6 Electrical Performances Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

P/N

Rated operating temperature

Tf(℃)

 

Actual operating temperature

(℃)

Hold temperature

Tc(℃)

Limit temperature

Tm(℃)

额定电压Rated Voltage

(V)

电流Rated Current

(A)

Breaking current

(A)

Limited time overload current

(A)

Y01 75 72±1 55 130 250 3 4.5 45
Y02 76 73±1 55 130 250 3 4.5 45
Y03 80 75±2 58 130 250 3 4.5 45
Y05 85 80±2 62 130 250 3 4.5 45
Y06 90 85±2 65 130 250 3 4.5 45
Y07 95 90±1 68 130 250 3 4.5 45
Y08 98 96±1 70 130 250 3 4.5 45
Y09 100 97±1 72 130 250 3 4.5 45
Y10 102 98±1 72 150 250 3 4.5 45
Y11 103 99±2 73 150 250 3 4.5 45
Y12 105 100±2 75 150 250 3 4.5 45
Y18 110 105±1 80 150 250 3 4.5 45
Y20 115 111±2 87 150 250 3 4.5 45
Y28 120 115±1 90 150 250 3 4.5 45
Y30 125 121±2 95 150 250 3 4.5 45
Y32 126 121±2 95 150 250 3 4.5 45
Y33 127 122±2 96 150 250 3 4.5 45
Y35 130 126±1 102 150 250 3 4.5 45
Y36 133 130±1 103 150 250 3 4.5 45
Y38 135 130±1 105 150 250 3 4.5 45
Y39 136 131±1 105 150 250 3 4.5 45
Y46 140 136±1 110 160 250 3 4.5 45
Y48 145 140±1 114 180 250 3 4.5 45
Y50 150 146±1 120 180 250 3 4.5 45

 

 

7 Company Introduction Of The The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

* Our company is located in Shilong Town, Dongguan City, Guangdong Province. It is a high-tech enterprise specializing in the production of thermal fuses.
* Since its establishment, the company has been committed to the development, production and application of thermal fuses. The products have passed CCC, VDE, TUV, UL, SGS certification, and the quality system has passed ISO9000 certification. The company has independent development capabilities and can develop various products required by customers in accordance with customer requirements. At present, the company's research and development capabilities, production control, product quality, and quality assurance capabilities have reached the advanced level in the same industry.
* The RH temperature fuse produced by our company is suitable for power transformers, power switches, sockets, rectifiers, fitness massagers, electric blankets, energy-saving lamps, communication tools and other household appliances. It is an indispensable safety for protecting electrical products and preventing electrical fires. Accessories. To
* The company adheres to the principle of "doing the job well the first time", with fast delivery as the main line, and reasonable price as the competitiveness, to provide manufacturers with satisfactory products and services.

 

 

8 Quality Assurance Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 4

 

 

9 More Products Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse

 

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 5

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 6

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 7

1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor 8

 

 

10 What are the characteristics of the Thermal Fuse?

 

 

Thermal fuse has the characteristics of accurate melting temperature, high withstand voltage, small size and low cost. The thermal fuse shell is marked with the rated temperature value and the rated current value, it is not difficult to identify, and it is very convenient to use. It can be widely used in electrical equipment, electric heating equipment and practical electrical appliances for overheating protection. Thermal fuse mainly has the following parameters:
① Rated temperature: Sometimes called the operating temperature or fusing temperature, it refers to the temperature at which the temperature rises to the fusing temperature at a rate of 1°C per minute under no-load conditions.
② Fusing accuracy: refers to the difference between the actual fusing temperature of the thermal fuse and the rated temperature.
③ Rated current and rated voltage: Generally, the nominal current and voltage of thermal fuse have a certain margin, usually 5A and 250V.
Thermal fuse is a one-time-use protection element. Its use affects not only depends on the performance of the element itself but more importantly, on how to select and install the thermal fuse correctly. The thermal fuse is generally connected in series in the circuit when it is used. Therefore, when choosing a thermal fuse, its rated current must be greater than the current used in the circuit. Never allow the current through the thermal fuse to exceed the specified rated current. Before selecting the rated temperature of the thermal fuse, you must understand and measure the temperature difference between the temperature to be protected and the location where the planting fuse is installed.
In addition, the length of the fusing time and the availability of ventilation are also closely related to the selection of the rated temperature of the thermal fuse.

Want to Know more details about this product
I am interested in 1A 2A 3A 5A 10A 15A 16A 250V Thermal Cutoff Fuse For Fan Motor could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.