SMD Chip 1025 Ceramic 300v Fast Acting Surface Mount Fuses UL 5A 500V
Product Details:
Place of Origin: | Dongguan,Guangdong,China |
Brand Name: | AMPFORT |
Certification: | UL,cUL,ROHS,REACH |
Model Number: | 1032F |
Payment & Shipping Terms:
Minimum Order Quantity: | 2000 PCS |
---|---|
Price: | Negotiable |
Packaging Details: | Reel,2K per reel |
Delivery Time: | 7-10 Workdays |
Payment Terms: | T/T,Paypal,Wire transer |
Supply Ability: | 10,000,000 Pieces Per Month |
Detail Information |
|||
Product Name: | 1025 Ceramic Fast Acting SMD Chip Fuse | Rated Voltage: | 300V 350V 400V 500V 600V |
---|---|---|---|
Current Range: | 200mA~5A | Fuse Type: | Fast Acting |
Small Size: | 10.2mm*3.2mm | Temperature Range: | -55°C To 125°C |
High Light: | 1025 Ceramic Surface Mount Fuses,300v Fast Acting Surface Mount Fuses,SMD Chip Fuse UL 5A 500V |
Product Description
1025 Ceramic Fast Acting SMD Chip Fuse 1032 200mA~5A 300V 350V 400V 500V 600V
Description Of The 1025 Ceramic Fast Acting SMD Chip Fuse 1032
1025 SMD chip fuse is designed to high inrush current application and high voltage available.Compared with 2410 smd fuse, 1025 fuse is a little bigger on size but higher current and higher voltage available.
Features Of The 1025 Ceramic Fast Acting SMD Chip Fuse 1032
► Fast acting
► 0.2A-5A current ratings
► Voltage up to 600V
► Hish inrush current capability
► Fast-acting high current fuse
► Compact design utilizes less board space
► Ceramic tube, gold or silver plated brass end cap construction
► Halogen free
► Server and desktop power supplies
► Gaming console systems
► Voltage Regulator Module (VRM)
► Storage system power
► Base station power supplies
► Basic power supplies
► LED and general lighting
► Test equipment
► UL CUL safety certifications
► ROHS REACH Complaint
► Tape in reel package
Specifications Of The 1025 Ceramic Fast Acting SMD Chip Fuse 1032
Part No. |
Ampere Rating |
Voltage Rating |
Breaking Capacity |
Nominal Cold Resistance (Ohms) |
I2TMelting Integral(A2.S) |
Agency Approvals |
||
UL | CUL | |||||||
1032F.0200 | 200mA |
300V/ 350V/ 400V/ 500VAC/DC |
600V AC/DC |
100A/@300V 350V 400V500V 600VAC/DC 150A@300V 350V 400V500V AC/DC
|
2.550 | 0.075 | ● | ● |
1032F.0250 | 250mA | 1.630 | 0.200 | ● | ● | |||
1032F.0300 | 300mA | 1.102 | 0.307 | ● | ● | |||
1032F.0315 | 315mA | 1.040 | 0.355 | ● | ● | |||
1032F.0375 | 375mA | 0.620 | 0.701 | ● | ● | |||
1032F.0500 | 500mA | 0.540 | 1.005 | ● | ● | |||
1032F.0630 | 630mA | 0.351 | 2.001 | ● | ● | |||
1032F.0800 | 800mA | 0.180 | 3.010 | ● | ● | |||
1032F.1100 | 1A | 0.177 | 3.811 | ● | ● | |||
1032F.1125 | 1.25A | 0.122 | 7.040 | ● | ● | |||
1032F.1150 | 1.5A | 0.072 | 10.92 | ● | ● | |||
1032F.1160 | 1.6A | 0.071 | 11.53 | ● | ● | |||
1032F.1200 | 2A | 0.055 | 13.40 | ● | ● | |||
1032F.1250 | 2.5A | --- | 0.041 | 26.12 | ● | ● | ||
1032F.1300 | 3A | 0.032 | 43.90 | ● | ● | |||
1032F.1315 | 3.15A | 0.031 | 44.60 | ● | ● | |||
1032F.1350 | 3.5A | 0.025 | 60.20 | ● | ● | |||
1032F.1400 | 4A | 0.023 | 62.90 | ● | ● | |||
1032F.1500 | 5A | 0.015 | 110.5 | ● | ● |
Breaking Capacity: 100A@300V350V400V500V600Vac/dc,
150A@300V350V400V500Vac/dc
% of Ampere Rating(In) |
Blowing Time |
100% * In | 4 hours Min |
200% * In | 120 sec Max |
Package Of The 1025 Ceramic Fast Acting SMD Chip Fuse 1032
Tape in reel, 2000pcs per reel.
Frequently asked questions Of The 1025 Ceramic Fast Acting SMD Chip Fuse 1032
Question | Answer |
Can fuses with an AC voltage rating be used in a DC voltage application? | Fuses should be rated for the voltage AC or DC in which they will be used. The data sheet will usually have both an AC and DC voltage rating if they are recommended for both types of applications. |
Do fuses need to be derated to account for the operating temperature? | Yes. Please contact technical support click here if the temperature derating information is not on the data sheet. |
What is the difference between interrupting rating (breaking capacity) and the fuse’s ampere rating? | The breaking capacity or interrupting rating for a protective device is the maximum available current, at rated voltage, that the device can safely open. The ampere rating is the normal current the fuse is designed to carry at +25 °C. It is recommended, however, that the fuse’s current rating be at least 125 percent of the nominal operating current passing through the fuse. Both ratings are determined through testing. |
My circuit is “x” amperes. What amperage fuse should I select? | The normal operating current of a circuit is the level of current drawn (in RMS or DC amperes) after it has been energized and is operating under normal conditions. An operating current of 80 percent or less of rated current is recommended for operation at +25 °C to avoid nuisance openings. For example, a fuse with a current rating of 1 A is usually not recommended in circuits with normal operating currents of more than 800 mA. Further derating is required at elevated ambient temperatures. |
Do fuse holders need derating? | Yes. Generally this derating factor is in line with fuse derating of 80 percent but could be more depending on additional environmental or operating factors such as temperature and/or current cycling. |
Can a time delay fuse be used to replace a fast acting fuse? | Fast acting fuses are typically used to protect sensitive components from damage. Time delay fuses are typically used in circuits that may have periodic spikes in current to avoid nuisance openings. Replacing fast acting fuses with a time delay fuse could result in damage to equipment. |