SMD 3 Gas 3 Pin GDT Discharge Tube 230V 20% 10kA Gas Tube Arrester
Product Details:
Place of Origin: | Dongguan,Guangdong,China |
Brand Name: | Ampfort |
Certification: | UL,CUL |
Model Number: | 8TL230M |
Payment & Shipping Terms:
Minimum Order Quantity: | 4000PCS |
---|---|
Price: | To be advised |
Packaging Details: | Plastic box packaging 100PCS per box, 4000PCS per carton. |
Delivery Time: | 7-10 Workdays |
Payment Terms: | T/T, Western Union,Paypal |
Supply Ability: | 500,000,000pcs per month |
Detail Information |
|||
Product Name: | Ceramic Gas Discharge Tube GDT | Number Of Pin: | 3pin |
---|---|---|---|
Suppressor Type: | 3 Electrode Gas Discharge Tube | Maximum Surge Current: | 10 KA |
DC Spark Over Voltage: | 230V(100v/s) | Impulse Spark Over Voltage (1kv/μs): | ≤600V |
Insulation Resistance: | ≥1GΩ | Electrode Capacitance 1MHz 0.5V: | ≤1.5PF |
Impulse Discharge Current: | 10KA (8/20μs 10times) | AC Discharge Current: | 10A(50Hz 1s 10times) |
Mounting Type: | Surface Mount | Dimensions: | 8x10mm |
High Light: | SMD 3 Gas Discharge Tube,3 pin GDT Gas Discharge Tube,230V 20% 10kA gas tube arrester |
Product Description
SMD 3 Electrode 3Pin Radial Ceramic Gas Discharge Tube GDT 8TL230M 230V 20% 10KA
GDT Operation Of The Ceramic Gas Discharge Tube GDT 8TL230M
GDT surge arrestor devices are designed to operate on the gas-physical principle of the highly effective arc discharge. Essentially a voltage dependent switch, the GDT maintains a high impedance off-state until a voltage exceeds the device’s sparkover voltage. At this point, the gas in the GDT becomes fully ionized and conduction takes place within a fraction of microsecond. During arc-over, the GDT exhibits the low impedance of a crowbar device resulting in very low on-state voltage (arc voltage). The crowbar effect of the GDT effectively limits the overvoltage to a low level and shunts the associated follow current away from downstream components and circuitry. When the surge event subsides and the system voltage returns to normal levels, the GDT will reset into its high impedance (off) state.
Technical Parameters Of The Ceramic Gas Discharge Tube GDT 8TL230M
Name: | Ceramic Gas Discharge Tube |
Part Number: | 8TL230M |
DC Spark-over Voltage: |
184-276V(Test conditions:Rise speed 100V/s) |
Impulse spark-over voltage: |
≤700V(Test conditions:Rise speed 1000V/µs) |
Insulation Resistance: |
≥1GΩ(Test conditions:DC 100V) |
Electrode Capacitance: |
≤1.5Pf(Test conditions:1MHz 0.5V) |
(Terms and current waveforms in accordance with ITU-T Rec.K.12; IEC61643-21) |
Resistance to 8/20μs Impulse Discharge Current 10KA±5times,Interval 60S |
Package: | Plastic box packaging 100PCS per box, 4000PCS per carton. |
Mounting: | Surface Mount |
Function: | Overvoltage protection |
Material Details Of The Ceramic Gas Discharge Tube GDT 8TL230M
No. | Part name | Material |
① | Electrode | Iron-nickel alloy |
② | Ceramic tube | AL2O3 |
③ | Intermediate electrode | Iron-nickel alloy |
④ | Electronic powder | Na2SiO3 etc |
⑤ | Lead wire | Tinned copper wire |
Series Part Numbering
This product is suitable for communication equipments and other electronic equipments for transient over-voltage protection against high voltage and lightning damage.
Catalog No. | DC Spark Over Voltage (100v/s)V | Impulse Spark Over Voltage (1kv/μs)V | Insulation Resistance GΩ | Electrode Capacitance 1MHz 0.5V PF | Impulse Discharge Current (8/20μs 10times) | AC Discharge Current (50Hz 1s 10times)A |
8TL075M | 75±20% | ≤600 | ≥1 | ≤1.5 | 10KA | 10A |
8TL090M | 90±20% | ≤600 | ≥1 | ≤1.5 | 10KA | 10A |
8TL150M | 150±20% | ≤600 | ≥1 | ≤1.5 | 10KA | 10A |
8TL230M | 230±20% | ≤700 | ≥1 | ≤1.5 | 10KA | 10A |
8TL350M | 350±20% | ≤1000 | ≥1 | ≤1.5 | 10KA | 10A |
8TL420M | 420±20% | ≤1000 | ≥1 | ≤1.5 | 10KA | 10A |
8TL470M | 470±20% | ≤1200 | ≥1 | ≤1.5 | 10KA | 10A |
8TL600M | 600±20% | ≤1400 | ≥1 | ≤1.5 | 10KA | 10A |
GDT Types Of The Ceramic Gas Discharge Tube GDT 8TL230M
Ampfort offers a broad range of 2-electrode and 3-electrode GDT devices (figures 2 & 3). 2-Electrode devices are typically used to provide line to ground or line to line protection (1 to 2). In a single device, a 3-electrode GDT can provide protection from line to line (1-2) as well as line to ground (1 to 3, 2 to 3) in a single device. Standard GDTs (75 to 600 V) are provided in both 2- and 3-electrode devices. High voltage GDTs (800 to 7200 V) are primarily offered in 2-electrode devices and some select 3-electrode packages. In addition, specialized GDTs are offered in high current, fast acting, hybrid and FLAT technology versions allowing the customer to address a wider array of protection needs.
GDT Benefits Of The Ceramic Gas Discharge Tube GDT 8TL230M
• 50+ years of designing and manufacturing GDT devices
• Impulse current ratings (2 kA to 100 kA)
• Low capacitance and insertion loss
• Designs based on industry standards
• Switch-Grade Fail-Short technology available on some models
• Technical committee participation and leadership
• Custom device capabilities
• Lab facilities available for design verification of customer circuits as well as with testing capabilities for UL and Telcordia standards
GDT Product Features Of The Ceramic Gas Discharge Tube GDT 8TL230M
• RoHS compliant*
• Wide range of voltages available (75 V to 7200 V)
• Wide range of sizes available
• Standard: GB/T9043-2008
• Low arc (on-state) voltage
• Low capacitance and insertion loss
• Non-radioactive materials
• Devices are tested according to U.S.A. and International standards and recommendations
• Low work function designs that result in long and stable service life
• UL497B SPD : E365642
Test methods of DC Spark-over Voltage Of The Ceramic Gas Discharge Tube GDT 8TL230M
The test circuit is shown in Figure 1. The DC voltage rise speed of test power supply is 100V/s, Discharging current is limited to 5~15mA. The positive and reverse polarity spark-over voltage of product should be tested in discharge inter-electrode. Has nothing to do with the test electrode should be left open.
Gas Discharge Tube Family