• S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C
  • S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C
  • S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C
  • S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C
  • S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C
S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C

Product Details:

Place of Origin: Dongguan,China
Brand Name: AMPFORT
Certification: ROHS
Model Number: HC06

Payment & Shipping Terms:

Minimum Order Quantity: 1000PCS
Price: 2~3 USD/PC
Packaging Details: Bulk,200pcs per bag
Delivery Time: 2 weeks
Payment Terms: T/T
Supply Ability: 10KKPCS Per month
Get Best Price Contact Now

Detail Information

Name: Thermal Protector Action Temperature: 50~180C
Tolerance: ±15℃ Close Temperature: 35-120C
Rated Current: 10A Rated Voltage: 250V
Size: 6.5*9mm Housing: Cu Environmental Protection Material
Package: Bulk Sleeve Material: Environmental Protection Materials With UL Certification
High Light:

Button Type Bimetal Thermal Protector

,

10A Bimetal Thermal Protector

,

160C Bimetal Temperature Switch

Product Description

 

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C

 

Description Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

The temperature switch is a temperature switch that uses a bimetallic sheet as a temperature sensing element. When the electrical appliance is working normally, the bimetallic sheet is in a free state, and the contact is in a closed/disconnected state. When the temperature rises to the operating temperature value, the bimetallic sheet is in a free state. The components are heated to generate internal stress and act quickly, open/close contacts, cut/connect the circuit, and thus play a role in thermal protection. When the temperature drops to the reset temperature, the contacts are automatically closed/opened, and the normal working state is restored. Widely used in home appliances motors and electrical equipment, such as washing machine motors, air conditioner fan motors, transformers, ballasts, electric heating appliances, etc.

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C 0

 

 

Use Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

This standard is applicable to the HC06 series protectors manufactured by Dongguan Ampfort Electronics Co., Ltd.

Temperature range: 60℃ ~180℃

Temperature tolerance: ± 5℃

All adhesive parts shall not displaced by 3.0kg

 

 

Characteristic Description Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

The product has ultra-thin volume, sensitive action and long life; 

With the dual protection function of overcurrent and temperature sensing; 

Use beryllium copper material with low resistance value to withstand the requirements of normal circuit current; 

The shell can be insulated and easy to install;

Electric leads can be selected according to customer needs;

The products strictly comply with the environmental protection standards of the EU ROHS Directive and the REACH Directive.

 

 

Certification and Life span Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

ROHS

In the conditions of rated voltage, current and power factor 0.7, the product can be normal on-off 2000 times operated due to external heat source.

A: The action temperature change shall be within + / -5℃ of the initial value;

B: Contact resistance shall be below 50mΩ(except for special wire or nickel sheet)

C: The electrical contact does not fuse or fall off; Continue the experiment to 10000 times.

 

 

Structure Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

Appearance 
The appearance size meets the product specifications and drawings of Dongguan Ampfort Electronics Co., LTD.; (See Note 2)
Connection method the standard product is wire, and the wire has UL certification (special according to customer requirements)
Housing Cu environmental protection material
Sleeve material environmental protection materials with UL certification

 

 

Note 1: Specification and temperature of HC06 series products

 

Action temperature code

Action temperature 

(℃) ±15℃

Close Temperature

(℃) ±15℃

HC06 050 50 ≥35
HC06 055 55 ≥35
HC06 060 60 ≥35
HC06 065 65 ≥35
HC06 070 70 ≥35
HC06 075 75 ≥35
HC06 080 80 ≥35
HC06 085 85 ≥35
HC06 090 90 ≥35
HC06 095 95 ≥35
HC06 100 100 67
HC06 105 105 70
HC06 110 110 72
HC06 115 115 75
HC06 120 120 78
HC06 125 125 82
HC06 130 130 85
HC06 135 135 90
HC06 140 140 93
HC06 145 145 95
HC06 150 150 100
HC06 155 155 102
HC06 160 160 105
HC06 165 165 110
HC06 170 170 115
HC06 175 175 118
HC06 180 180 120

Reset temperature is for reference only, and other temperature specifications can be customized.

 

 

Size and Structure Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C 1

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C 2

No. Name Material
1 Tube PEI Insulating paper
2 Housing Copper
3 Positioning post Copper
4 Bimetal iron/nickel/copper
5 Shrapnel Stainless steel
6 Current plate Silver copper composite board
7 Copper ring Copper
8 Silver contacts Copper silver composite
9 Base Ceramic
10 Terminal Copper
11 Electronic wire *2

 

 

Performance Of The HC06 Series Bimetal Thermal Protector 10A 250V

 

1) Rated electrical parameters: AC250V,10A

2) Operation temperature: See Note 1 ;

3) Insulation voltage:Between the wire and the insulation shell can withstand AC1500V, 1 minute or AC1800V,1 second without breakdown phenomenon, electricity leakage The flow shall be below 1mA;

4) Insulation resistance:Under normal conditions, the insulation resistance between leads (terminal) and case should be more than 100MΩ measured by ohmmeter of DC500V.

5) Contact resistance: The contact resistance of standard lead length products should be lower than 50mΩ .

6) High temperature test: Keep the thermal protector in an incubator environment of 30 degree higher than its rated switching temperature for ninety six hours,and test it two hours later after taking out from the incubator, while the temperature change does not exceed the initial value of ± 5 ℃ or ± 5%,returns the maximum value.

7) Low temperature resistance test: Keep the thermal protector in a -40℃ incubator for ninety six hours, and test it two hours later after taking out from the incubator, while the temperature change does not exceed the initial value of ± 5 ℃ or ± 5%, returns the maximum value.

8) Anti-Vibration test: thermal protector should be able to withstand the amplitude 1.5mm, frequency 10 ~ 55Hz, scanning change cycles of 3 ~ 5 times /min. The vibration direction X, Y, Z and each direction vibrates on a continuous basis for 2 hours while the temperature change does not exceed the initial value of ± 5 ℃ or ± 5%, returns the maximum value.

9) Ultimate short-circuit test:When the thermal protector is in series connection with RL1-15A fuse to withstand short circuit current limit of 200A, it should not cause the cotton burned which is wrapped on the thermal protector.

10) Wet resistance experiment:The product is placed in 40℃ temperature and 95% relative humidity for 48 hours;

11) Tensile resistance test: Terminal & leads should endure more than 30N axes direction pull lasting for 1 minute without break or looseness

12) Drop experiment:Product from 70cm height free fall to the floor (plastic or wooden floor)

The following conditions should be met after the above experiments:

A: Action temperature change within + / -7℃ of the initial value;

B: The contact resistance shall be less than 50m Ω

C: The appearance shall have no obvious deformation;

D: No cracking damage of the conductor.

S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C 3

Want to Know more details about this product
I am interested in S01 S02 Button Type Normal Close Open HC06 Series Bimetal Thermal Protector 10A 250V 160C 165C 170C 175C 180C could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.