Temperature Protection Ceramic Tube Thermal Fuse 120C 16A 250V For Home Appliances Instant Electric Faucet
Product Details:
Place of Origin: | CHINA |
Brand Name: | CNAMPFORT |
Certification: | CCC |
Model Number: | HF120 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1000 |
---|---|
Price: | Negotiable |
Packaging Details: | Bulk |
Delivery Time: | 10 Workdays |
Payment Terms: | T/T |
Supply Ability: | 100KKPCS PER MONTH |
Detail Information |
|||
Name: | Ceramic Tube Thermal Fuse | Housing: | Ceramic |
---|---|---|---|
Diameter: | 7.5mm | Total Length: | 58mm,89mm,90mm,125mm |
Function Temperature: | 120C | Rated Voltage: | 250V |
Rated Current: | 16A | Terminal: | Faston |
Highlight: | 120C Ceramic Tube Thermal Fuse,250V Ceramic Tube Thermal Fuse |
Product Description
Temperature Protection Ceramic Tube Thermal Fuse 120C 16A 250V For Home Appliances Instant Electric Faucet
The electric faucet temperature fuse is an overheat protection element installed in the electric faucet. The main part of the electric faucet temperature fuse is made of ceramic, also known as the electric water heater thermal fuse; ceramic temperature fuse. It is a temperature induction circuit cut-off device, which is used to ensure that the overheating generated in the abnormal operation of the electric faucet heating equipment causes burns or fires and other accidents. Temperature fuse is a very critical component. Usually the surface of the product is marked with temperature and current.
Working Principle:
When the temperature around the thermal fuse rises to its operating temperature, the fusible alloy melts and under the help of surface tension and special resin, the fusible alloy wire breaks and shrinks into a spherical shape attached to the end of the two pins. In this way, the circuit is permanently cut off. So as to avoid happening outside!
P-series products are widely used for overheating protection of various small power motor coils,electric faucet .
1. Fast response: The thermal fuse of the instant electric faucet has a very fast response speed. When the water temperature reaches the set value or exceeds the safety range, the fuse can be blown in a very short time, cut off the power supply, and prevent the electric heater from continuing to heat, thereby ensuring the safety of users.
2. Safe and reliable: The main function of the thermal fuse is to cut off the power supply in time when the electric faucet fails or is abnormal, so as to avoid the occurrence of safety accidents such as electric shock and leakage. Therefore, the temperature fuse plays a vital role in the safety protection of the instant electric faucet.
3. High temperature resistance: During the working process of the instant electric faucet, the water inside it will continue to circulate and heat. Therefore, the temperature fuse needs to have high temperature resistance to work normally in a high temperature environment and ensure the stable operation of the electric faucet.
4. High voltage resistance: Since the instant electric faucet needs to heat the water to a higher temperature, it will generate a higher voltage during the working process. In order to ensure that the temperature fuse can withstand this high-pressure environment, its internal structure and materials need to be specially designed to improve the withstand voltage performance.
5. High current capacity: the hot electric faucet needs to withstand a large current during the working process, so the temperature fuse needs to have a high current capacity to work normally under high current and ensure the stable operation of the electric faucet.
6. Easy to replace: In order to ensure the safety of users during use, the temperature fuse of the instant electric faucet is usually designed to be detachable, which is convenient for users to replace as needed during use. At the same time, the process of replacing the fuse is relatively simple, and the user can operate according to the instructions without the guidance of profession
Unit:mm
Model No. | a | b | c | d | e |
P-1A-F | 6.5 ± 0.5 | 38 ± 3 | Φ0.54± 0.05 | Φ2.1± 0.1 | 2.4 or below |
Model No | a | b | c | d | e |
P-F | 9.0± 0.5 | 38 ± 3 | Φ0.54± 0.05 | Φ2.5± 0.1 | 3.0 or below |
Model NO. | Tf(℃) | Fusing-off temp. (℃) | Th(℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | Corp | ||||||
P1-1A-F | 102 | 92-102 | 98±2 | 80 | 200 | 1 | 250 |
P2-1A-F | 115 | 105-115 | 112±3 | 99 | 200 | 1 | 250 |
P3-1A-F | 125 | 115-125 | 120±3 | 105 | 200 | 1 | 250 |
P4-1A-F | 130 | 120-130 | 126±2 | 107 | 200 | 1 | 250 |
P5-1A-F | 135 | 125-135 | 131±3 | 115 | 200 | 1 | 250 |
P9-1A-F | 138 | 128-138 | 135±2 | 118 | 200 | 1 | 250 |
P12-1A-F | 145 | 135-145 | 140±2 | 126 | 200 | 1 | 250 |
P7-1A-F | 150 | 140-150 | 145±3 | 128 | 200 | 1 | 250 |
P15-1A-F | 223 | 213-223 | 218±2 | 190 | 280 | 1 | 250 |
P01-1A-F | 76 | 76+0/-10 | 72±2 | 55 | 180 | 1 | 250 |
Model NO. | Tf(℃) | Fusing-off temp. (℃) | Th(℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | Corp | ||||||
P1-F | 102 | 102+0/-10 | 98±2 | 80 | 200 | 2 | 250 |
P2-F | 115 | 115+0/-10 | 112±3 | 99 | 200 | 2 | 250 |
P3-F | 125 | 125+0/-10 | 120±3 | 105 | 200 | 2 | 250 |
P4-F | 130 | 130+0/-10 | 126±2 | 107 | 200 | 2 | 250 |
P5-F | 135 | 135+0/-10 | 131±3 | 115 | 200 | 2 | 250 |
P9-F | 138 | 138+0/-10 | 135±2 | 118 | 200 | 2 | 250 |
P12-F | 145 | 145+0/-10 | 140±2 | 126 | 200 | 2 | 250 |
P7-F | 150 | 150+0/-10 | 145±3 | 128 | 200 | 2 | 250 |
P15-F | 223 | 223+0/-10 | 218±2 | 190 | 280 | 2 | 250 |
P01-F | 76 | 76+0/-10 | 72±2 | 55 | 200 | 2 | 250 |
Product Certification
P-series products meet the safety test requirements of IEC 60691 Ed 4.0 and GB/T 9816.2013, and many models are certified with UL, VDE, CCC, PSE, KC, TUV and other safety approvals.
Model No. | UL/CUL | VDE | CCC | PSE | KC |
P1-1A-F | E140847 | 40002523 | 2020980205000148 | JET0749-32001-1003 | SU05017-5008C |
P2-1A-F | |||||
P3-1A-F | JET0749-32001-1004 | SU05017-5007C | |||
P4-1A-F | |||||
P5-1A-F | |||||
P9-1A-F | |||||
P12-1A-F | JET0749-32001-1006 | ||||
P7-1A-F | |||||
P15-1A-F | x | x | x | x | x |
Model No. | UL/CUL | VDE | CCC | PSE | KC |
P1-F | E140847 | 40000032 | 2020980205000147 | JET0749-32001-1003 | SU05017-5005C |
P2-F | |||||
P3-F | JET0749-32001-1004 | SU05017-5006C | |||
P4-F | |||||
P5-F | |||||
P9-F | |||||
P12-F | JET0749-32001-1006 | ||||
P7-F | |||||
P15-F | x | x | x | x | x |